Scinomix SCINOMIX VXQ Bulk Tube Feeder

Request a Quote

Fill in your details below to receive a quote on this item. Our team will be in touch as soon as possible.

Note: We require email addresses from workplace domains only. If you have an email address containing gmail.com, yahoo.com, etc. please call 1-877-267-4272 to talk to a representative.

Model No: 1071 Rev.B

Serial No: 0821

Product ID: 12876a

The Scinomix VXQ is a bulk tube handler that eliminates handloading of tubes into racks to provide even more time savings. The Scinomix VXQ is compatible with a range of tubes from 0.5 ml to 15 ml (the collar of the tube must be wider than the body of the tube). This flexible design allows the user to easily change tube types with the touch of a button.

The Scinomix VXQ was developed to be paired with the VX Series tube labeling systems, the Sci-Print VX2 and the Sci-Print VXL. Both of these systems have a variety of functions including printing and labeling, filling, uncapping/recapping of screw top lids, and barcode scanning.

An optional 2D barcode scanner can be added to the systems for verification or to reprint the barcode on the label. When the VXQ is paired with one of these systems, it can handle 200-300 bulk tubes per hour.

Features
  • Handle multiple tube types with same system
  • Throughput up to 400 tubes per hour
  • Works with a variety of vials ranging from 0.5 mL to 15mL
  • Touch screen control
  • Easily create, store and change multiple tube definitions
  • Retrofits to existing machines in the field 


Air Requirements:80-90 PSI @ 1 CFM. The air supply must be oil/contaminant free, with an inline regulator and air dryer.

Main Power Requirements:110-240 VAC 50/60 Hz 80W (Max)

Provided Power Supply:Output Voltage: 24 V DC Max Output Current: 2.71 A Max Output Power: 65 W Max Ripple and Noise: 240 mV p-p

Operating Environment:(Indoor use only) Temperature: 10 degrees C to 40 degrees C Humidity: 20% to 80% non-condensing Altitude: Up to 2000M Main Supply: +/- 10% Rated Voltage Transient overvoltage: Installation Category (Overvoltage category) II Rated pollution: Pollution degree II

Transport & Storage Temperature:-20 degrees C to +55 degrees C (20% to 80% non-condensing)

Physical Dimensions:Height: 19.93”(491.9mm), Width: 23.93”(607.8mm), Depth: 19.37”(491.4mm), Weight: 52 lbs. (24KG)

Hopper Capacity:Contingent on type type/size being used. For reference, the hopper can hold up to 600 Cryovials

Tube Specifications:Volume Range: 0.5 mL to 15 mL*, Max Height: 125 mm, Max Diameter: 18 mm

Certifications:CE

Go back