Microplate Reader

BMG Labtech PHERAstar FSX Microplate Reader

Request a Quote

Fill in your details below to receive a quote on this item. Our team will be in touch as soon as possible.

Note: We require email addresses from workplace domains only. If you have an email address containing gmail.com, yahoo.com, etc. please call 1-877-267-4272 to talk to a representative.

Model No: 24094

Serial No: 472-1060

Product ID: 12940

The PHERAstar®FSX is our most sensitive multi-mode reader for high-throughput screening, combining this sensitivity with fast read times. Thanks to the unique Optic Module system, Simultaneous Dual Emission, UV/vis spectrometer, and dedicated AlphaScreen® and TRF lasers, the PHERAstar FSX will perform your assay with ease and speed, even in 3456-well microplates.


PHERAstar FSX

  • Detection Modes
  • Fluorescence intensity - incl. FRET
  • Fluorescence polarization
  • AlphaScreen®/AlphaLISA®/AlphaPlexTM
  • Luminescence (flash and glow) - incl. BRET
  • Time-resolved fluorescence
  • TR-FRET
  • UV/Vis absorbance spectra
  • Measurement Modes
  • Top and bottom reading
  • Endpoint and kinetic
  • Sequential multi-excitation
  • Sequential multi-emission
  • Simultaneous Dual Emission
  • Spectral scanning (absorbance)
  • Real-time ratiometric measurements
  • Well scanning
  • Microplate Formats
  • Up to 3456-well plates, user-definable
  • LVis Plate with 16 low volume microspots (2 μL)
  • Microplate Carrier
  • Robot compatible
  • Light Sources
  • High energy xenon flash lamp
  • Dedicated laser for AlphaScreen®/AlphaLISA®/AlphaPlexTM
  • Dedicated laser for TRF and TR-FRET
  • Detectors
  • Two matched pairs of photomultiplier tubes (PMTs), optimized for different detection modes 
  • CCD spectrometer
  • Wavelength Selection
  • Optic Modules: Up to six application-specific modules (includes all filters, dichroics, etc. for an application) 
  • For top and bottom reading
  • UV/vis absorbance spectrometer: Full spectra or 8 distinct wavelengths in < 1 sec / well
  • Optical Path Guides
  • Top and bottom: free-air optical light path guided by motor-driven mirrors and dichroics
  • Z-Adjustment
  • Automatic focal height adjustment (0.1 mm resolution)
  • Spectral Range
  • Filters 230 - 750 nm or 230 - 900 nm for FI, FP
  • 230 - 750 nm for LUM
  • 230 - 900 nm for TRF Spectrometer 220 - 1000 nm for ABS; wavelength precision: ≤ 0.5 nm 
  • Sensitivity
  • FI
  • (top) < 0.15 pM FITC (384sv black, 20 μL)
  • < 0.5 pM FITC (1536 black, 8 μL) FI
  • (bottom) < 1.0 pM FITC (384g black, 50 μL) FP < 0.5 mP SD at 1 nM FITC (384sv black, 20 μL)
  • < 1.5 mP SD at 1 nM FITC (1536 black, 8 μL) TRF
  • with laser < 5 fM europium (384, 80 μL)
  • < 15 fM europium (1536, 8 μL)  HTRF®
  • (black and white microplates) Reader Control Kit (Eu) after 18h (384sv, 20 μL)
  • Delta F > 1100 % (High Calibrator)
  • Delta F > 25 % (Low Calibrator) LUM < 0.4 pM (< 8 amol/well ATP, 384sv white, 20 μL)
  • Dynamic Range: 9 decades AlphaScreen®
  • with laser < 5 pM (< 100 amol/well P-Tyr-100, 384sv white, 20 μL) ABS
  • with spectrometer Selectable spectral resolution: 1, 2, 5, and 10 nm
  • OD range: 0 to 4 OD; photometric resolution: 0.001 OD
  • Accuracy: < 1% at 2 OD
  • Precision: < 0.5% at 1 OD and < 0.8% at 2 OD 
  • Linearity: ≤ 0.8% at 2.0 OD
  • Read Times
  • Flying mode
  • (1 flash) 14 s (384)
  • 27 s (1536) 
  • 10 flashes 38 s (384)
  • 1 min 52 s (1536) 50 flashes 1 min 29 s (384)
  • 5 min 18 s (1536) 
  • Reagent Injection
  • Up to 2 built-in reagent injectors
  • Injection at measurement position (6 to 384-well)
  • Individual injection volumes for each well (3 to 500 µL, optionally up to 2 mL)
  • Variable injection speed up to 420 µL / s
  • Up to four injection events per well
  • Reagent back flushing
  • Shaking
  • Linear, orbital, and double-orbital with user-definable time and speed
  • Integrated Barcode Reader
  • Up to three integrated barcode readers
  • Incubation
  • +5 °C above ambient up to 45 °C

  • The upper heating plate of the incubation chamber operates at 0.5 °C more than the lower plate. This prevents condensation build-up on the lid or sealer.
  • Software
  • Multi-user Reader Control and MARS Data Analysis Software included 
  • FDA 21 CFR Part 11 compliant
  • Dimensions
  • Width: 45 cm, depth: 51 cm, height: 47 cm; weight: 49 kg
  •  

Go back